• Supernova Perkins

9kVA to 2250kVA

22500 kVA When paralleled

Supernova Diesel Electric Gensets are powered by Perkins Diesel Engine ranging from 9 kVA to 2250 kVA. Each Supernova Diesel Electric Genset is manufactured under stringent quality assurance process and undergoes in-house testing. Engine performance corresponds to ISO 3046, BS 5514 and DIN6271. The technical data applies to an engine operating on a fuel with a calorific value of 42.7 MJ/Kg(10200 Kcal/Kg) and a density of 0.86 Kg/Litre and as per BS 2869 Part 21998 Class A2 or ASTM D975D2. AC Generator performance corresponds to IEC-34, IS-4722

Salient Features

  • Six Cylinder in Line upto 750 & 800 kVA, eight Cylinder lnline for 1010 kVA
  • Twelve Cylinder VEE Engine from 1250 kVA to 1700 kVA D. G. Set application
  • Compact Size for Easier Transportation and Installation
  • High Block Loading Capability
  • Commonality of Components Over the Entire Series of Engines
  • Low Operating and Maintenance cost
  • Excellent Power to Weight Ratio
  • Designed to Provide Excellent Service Access for Ease of Maintenance
  • Types for D.G. Sets

    • Open Type D.G. Sets
    • Silent D.G. Sets (Acoustically treated)
    • Containerized D. G. Sets (Acoustically treated)

    Standard Scope Comprising Of

    • Diesel Engine / AC Generator / base frame / Standard Control Panel /
    • Radiator / Silencer / Battery & Battery Cables / AVMs / First Fill of
    • Lub. Oil / First Fill of Coolant / D. G. Set Controller / fuel tank /
    • wiring harness / Sensors.

    Options Available

    • Voltage Options: LT-380/415 VI HT-3.3/6.6 /11 kv
    • Cooling Systems: Remote Radiator I Heat Exchanger
    • Electrical Options: Auto Mains Failure / Auto Synchronizing Panels / CRM / NIS / NGRNCB
    • Standard Switchgear- L& T /Schneider, other makes can be offered on request
    • Standard Controllers-Woodward/DIEF/DeepSea, other makes can be offered on request

    Rating Table

    Radiator Cooled
    Prime Power
    1500RPM (50Hz) 3 Ph., 415V, 0.8 PF
    Overall Dimensions
    (Acoustic Enclosure)
    Genset Model Engine Model BHP Rated kVA Rated kW Length Width Height
    SP 9 403A-11G1 11.5 9 7.2 2000 1000 1348
    SP 15 403A-15G2 18 15 12 2000 1000 1348
    SP 20 404A-22G 25 20 16 2000 1000 1348
    SP 20 404D-22G 25.1 20 16 2000 1000 1348
    SP 30 1103A-33G 37.8 30 24 2750 1150 1665
    SP 45 1103A-33TG1 56.6 45 36 2750 1150 1665
    SP 60 1103A-33TG2 73.7 60 48 2750 1150 1665
    SP 80 1104A-44TG2 98 80 64 3350 1150 1770
    SP 100 1104C-44TAG2 125.5 100 80 3350 1150 1770
    SP 135 1106A-70TG1 164.5 135 108 3800 1500 1900
    SP 150 1106A-70TAG2 182.4 150 120 3800 1500 1900
    SP 200 1106A-70TAG4 239.8 200 160 3800 1500 1900
    SP 250 1506A-E88TAG3 344 200 160 4100 1650 1900
    SP 300 1506A-E88TAG5 412 200 160 4500 1800 2160
    SP 400 2206A-E13TAG3 493 400 320 5000 2000 2235
    SP 500 2506A-E15TAG2 605 500 400 5550 2000 2340
    SP 600 2806A-E18TAG1A 721 600 480 5550 2000 2340
    SP 650 2806A-E18TAG2 783 650 520 5550 2000 2340
    SP 750 4006-23TAG2A 882 750 600 7000 2150 2520
    SP 800 4006-23TAG3A 945 800 640 7000 2150 2520
    SP 911 4008 TAG1A 1080 911 728 7200 2150 2520
    SP 900 4008-30TAG1 1080 900 720 7200 2150 2520
    SP 1010 4008-30TAG2 1206 1010 808 7200 2250 2520
    SP 1022 4008-TAG 2A 1206 1022 818 7200 2150 2520
    SP 1125 4008-30TAG3 1270 1125 900 7200 2250 2520
    SP 1250 4012-46 TWG2A 1492 1250 1000 12192 2438 2895
    SP 1250 4012-46 TAGOA 1497 1250 1000 12192 2438 2895
    SP 1364 4012-46 TAG1A 1625 1364 1091 12192 2438 2895
    SP 1364 4012- 46 TWG3A 1618 1364 1091 12192 2438 2895
    SP 1500 4012-46 TAG2A 1785 1500 1200 12192 2438 2895
    SP 1500 4012- 46 TWG4A 1762 1500 1200 12192 2438 2895
    SP 1700 4012-46 TAG3A 2006 1700 1360 12192 2438 2895
    SP 1850 4016-61 TRG1 2208 1850 1480 12192 2438 2895
    SP 2000 4016-61 TRG2 2377 2000 1600 12192 2438 2895
    SP 2250 4016-61 TRG3 2647 2250 1800 12192 2438 2895
    Radiator Cooled
    Stand by Power
    1500RPM (50Hz) 3 Ph., 415V, 0.8 PF
    Overall Dimensions
    (Acoustic Enclosure)
    Genset Model Engine Model BHP Rated kVA Rated kW Length Width Height
    SP 825(S) 4006-23 TAG2A 967 825 660 7000 2150 2520
    5P 900 (S) 4006-23TAG3A 1054 900 720 7000 2150 2520
    SP 1000 (S) 4008-30TAG1 1408 1000 800 7000 2150 2520
    SP 1002 (S) 4008TAG1A 1183 1002 802 7000 2150 2520
    SP 1125 (S) 4008-TAG 2A 1321 1125 900 7200 2150 2520
    SP 1125 (S) 4008-30TAG2 1321 1125 900 7200 2150 2520
    SP 1250(S) 4008-30TAG3 1408 1200 1000 7200 2150 2520
    5P 1375 (S) 4012-46 TAGOA 1638 1375 1100 12192 2438 2895
    5P 1385 (S) 4012-46 TWG2A 1641 1385 1108 12192 2438 2895
    5P 1500(S) 4012-46 TAG1A 1780 1500 1200 12192 2438 2895
    SP 1500(S) 4012-46 TWG3A 1772 1500 1200 12192 2438 2895
    SP 1650 (S) 4012-46 TAG2A 1957 1650 1320 12192 2438 2895
    5P 1600(S) 4012-46TWG4A 1931 1600 1280 12192 2438 2895
    SP 1880(S) 4012-46 TAG3A 2203 1880 1504 12192 2438 2895
    SP 2000(S) 4016-61 TRG1 2377 2000 1600 12192 2438 2895
    SP 2250(S) 4016-61 TRG2 2659 2250 1800 12192 2438 2895
    5P 2500(S) 4016-61 TRG3 2925 2500 2000 12192 2438 2895

    Rating Guidelines

    Prime Power rating corresponds to ISO standard power for continuous operation. It is applicable for supplying electrical power at variable load for an unlimited number of hours instead of commercially purchased power. This is as per ISO 8528.
    Stand by Power: Rating corresponds to ISO fuel stop power. It is applicable for supplying standby electrical power at variable load in area with well-established electrical networks, in the event of power failure. No overload is available with this rating.
    The warranty services shall be offered through authorized Perkins dealers in the respective areas as per the standard procedure of Perkins India Pvt. Ltd.
    All equipment has a warranty either against faulty workmanship or manufacturing defects for a period of 15 months from the date of dispatch or 12 months from the date of commissioning for unlimited number of hours. This warranty is back to back basis from our respective principals, engine and alternator manufacturers. This shall however exclude rubber parts and electrical gauges, faults due to mishandling, misuse or improper operation and maintenance
    All equipment has a warranty either against faulty workmanship or manufacturing defects for a period of 26 months from the date of dispatch or 24 months from the date of commissioning or 6000 hours whichever is earlier. This warranty is back to back basis from our respective principals, engine and alternator manufacturers. This shall however exclude rubber parts and electrical gauges, faults due to mishandling, misuse or improper operation and maintenance.

    Industries Catered

    icon-about-listen

    Bank

    icon-about-dream

    Corporate

    Government

    icon-about-listen

    Hotel

    Data Centre

    icon-about-listen

    Telecom

    icon-about-dream

    IT

    icon-about-listen

    Infrastructure

    Manufacturing

    icon-about-dream

    Hospital

    CAN'T GET ENOUGH?

    Please sign up for our email blasts and latest newsletters.

    Please Enter Your Email Id ! Please Enter Valid Email Id !